OSS – Output switching signals

 
OSS1 (Ouput 1) linked to pin/wire number 4. Works as an IO-link pin when connected to an IO-Link master


OSS2 (Output 2) linked to pin/wire number 4. Can also be configured as an SIO Input on DMS Sensors.

Configure Output(s)
1
Inactive

Set Output to Inactive during maintenance and test procedures.

2
Active

Set Output to Active.
Set output logic to:
High Active (NO) or Low Active (NC)

Select internal source signal to be redirected to the output pin.

*Only for Inductive DMS sensors *

Conditional Output Logic

Optionally combine internal signals and alarms and/or an external signal from OSS2 input.
Use AND, OR or XOR functions to define conditional output logic.

Configure Output 2 as an Input

Configure OSS2 (Output 2) as an input signal to be used in logical functions of OSS1 (Output 1). 

Useful for daisy chaining of multiple sensors or devices. 

Configure Output 2 as an Input to trigger a single value teach on SSC1 (switchpoint 1).